Last edited by Yorr
Thursday, May 7, 2020 | History

3 edition of IEEE guide for motor operated valve (MOV) motor application, protection, control, and testing in nuclear power generating stations found in the catalog.

IEEE guide for motor operated valve (MOV) motor application, protection, control, and testing in nuclear power generating stations

IEEE guide for motor operated valve (MOV) motor application, protection, control, and testing in nuclear power generating stations

  • 305 Want to read
  • 15 Currently reading

Published by Institute of Electrical and Electronics Engineers in New York, NY .
Written in English

    Subjects:
  • Nuclear power plants -- Equipment and supplies -- Standards,
  • Nuclear power plants -- Piping -- Valves -- Standards,
  • Nuclear reactors -- Safety measures -- Standards

  • Edition Notes

    Statementsponsor, Nuclear Power Engineering Committee of the IEEE Power Engineering Society.
    SeriesIEEE Std -- 1290-1996., IEEE std -- 1290-1996.
    ContributionsIEEE Power Engineering Society. Nuclear Power Engineering Committee.
    The Physical Object
    Paginationvi, 68 p. :
    Number of Pages68
    ID Numbers
    Open LibraryOL17434530M
    OCLC/WorldCa36313888

    Method of Operation > Electric Actuators Valves are opened and closed by a reduction gear that transmits force to a drive shaft that is connected to the valve's stem. Positional control for opening and closing the valve is achieved through a limit switch. Figure Gate valve 34 Figure Relief valve 36 Figure Electric Solenoid Actuator 38 Figure Typical piston actuators 39 Figure Diaphragm actuator 40 Figure Valve and actuator configurations 41 Figure Direct acting actuator and reverse acting control valve 42 Figure Centrifugal pump 43 Figure Mechanical seal

    ICDE Project Report: Collection and Analysis of Common-Cause Failures of Motor Operated Valves February JT Document complet disponible sur OLIS dans son format d’origine Complete document available on OLIS in its original format NEA/CSNI/R()10 Unclassified English text only. Install Guide Boost Simulation Accuracy & Productivity Multi-Language Edition - Localized • Motor Operated Valve Dynamic Voltage Limits • Korean • Russian • Portuguese • Spanish • Italian* •» IEEE ExcitersTurkish* *Output Reports • Blazing performance up to 50 X faster • Over 50 New UDM Models» IEEE PSS.

      A ball valve, requiring only 1/4 turn might be a bit simpler but changing the ball valve to a piston valve requiring only a simple linear motion is a very attractive option and some automated valves are designed in just that way. Solenoids are simple and do a nice job of providing linear motion. Electric Motor Operated Grooved End Butterfly Valves and Air Operated Grooved End Butterfly Valves. Also Available ISO Mount Bare Stem Grooved End Butterfly Valve for Valve Automation Centers. Considerably Lower Prices than Grooved End Butterfly Manufacturers. Perfect .


Share this book
You might also like
APEC trade liberalisation

APEC trade liberalisation

Nuffield physics

Nuffield physics

British Columbia modern history, 1740s-1970s

British Columbia modern history, 1740s-1970s

Literary origins of surrealism

Literary origins of surrealism

Soil enzymes

Soil enzymes

Introduction to soil microbiology

Introduction to soil microbiology

Written comments on H.R. 1233, the Caribbean Basin Economic Recovery Expansion Act of 1989

Written comments on H.R. 1233, the Caribbean Basin Economic Recovery Expansion Act of 1989

Directory of organization.

Directory of organization.

Ice hockey: Research, development, and new concepts = Le hockey sur glace

Ice hockey: Research, development, and new concepts = Le hockey sur glace

System and signal analysis

System and signal analysis

Foreword to the I ching

Foreword to the I ching

UNs mutual aid

UNs mutual aid

Vegetation of Stewart Island, New Zealand

Vegetation of Stewart Island, New Zealand

IEEE guide for motor operated valve (MOV) motor application, protection, control, and testing in nuclear power generating stations Download PDF EPUB FB2

IEEE IEEE Guide for Motor Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power Generating Stations [IEEE] on *FREE* shipping on qualifying offers.

IEEE IEEE Guide for Motor Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power Generating StationsAuthor: IEEE. : IEEE IEEE Guide for Motor-Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power-Generating Stations: Everything Else.

IEEE Guide for Motor Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power Generating Stations Edition: $ Unlimited Users - 1 Loc per year. IEEE Guide for Motor Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power Generating Stations.

Publisher: [Place of publication not identified]:. IEEE Guide for Motor-Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power-Generating Stations. buy ieee guide for motor-operated valve (mov) motor application, protection, control, and testing in nuclear power-generating stations from sai global.

The motor operated valves (MOV) is an important element of the plant and pipe system. These valves are generally large and are used for different applications such as pump discharge, etc.

The control valves operated by motor are often called on / off valves since the motors serve to open or completely close the valves in the pipes.

IEEE IEEE Guide for Motor-Operated Valve (MOV) Motor Application, Protection, Control, and Testing in Nuclear Power-Generating Stations. standard by IEEE, 10/02/ View all product details.

Motors used to drive valve operators in nuclear power generating stations are discussed. Guidelines to evaluate the adequecy of motors used to drive valve operators; to provide recommendations for motor applications; and to provide methods for protection, control, and testing of motors used for valve operation are presented.

ieee c guide for the application of surge voltage protective equipment on ac rotating machinery v and greater: ieee guide for motor-operated valve (mov) motor application, protection, control, and testing in nuclear power-generating stations: ieee IEEE Guide for the Commissioning of Electrical Systems in Hydroelectric Power Plants* John Yale P Working Group Chair Hydro Plant Engineering Manager Chelan County PUD * pages of joyful reading.

Scope • Checkout of motor operated valves, dampers and gates;File Size: KB. This presentation provides an introductory look at motor operated valves, with a focus on the manufacturer Limitorque.

The document includes the theory of operation of MOVs plus descriptions of valve types, such as gate, globe, ball, plug and butterfly.

IEEE Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications Abstract: Superseded by IEEE Std Methods for selecting the appropriate type of valve-regulated, immobilized-electrolyte, recombinant lead-acid battery for any of a variety of potential stationary float applications are described.

ELECTRIC MOTOR VALVE ACTUATOR FUNCTION TEST Test Equipment Required: Volt Supply Multimeter Clamp-on Meter Megger Tester Typical Test Set-up Functional Test Procedure a.

Check motor spec as per datasheets. Check motor winding insulation resistance and record it. Hook-up instrument as per typical set-up. Confirm valve. VSS (IEEE StdDOE O B, DOE G -1, etc.). Electrical personnel shall demonstrate a familiarity level knowledge of electrical safety design requirements for VSS Motor Operated Valves (MOV) (IEEE StdDOE O B, DOE G -1, etc.).File Size: 5MB.

20 - Elect. operated valve (solenoid valve) 21 - Distance Relay 23 - Temperature Control Device 24 – Volts per Hertz Relay 25 - Synchronizing or Synchronism-Check Device 26 - Apparatus Thermal Device 27 - Undervoltage Relay 29 - Isolating Contactor 30 - Annunciator Relay 32 - Directional Power Relay 36 - Polarity or Polarizing Voltage Devices.

Motor operated valve type ICMTS with actuator, type ICAD A-TS Danfoss | DCS (MWA) | 0.B | H | 1 The ICMTS is a direct operated motorised valve driven by actuator type ICAD A-TS. The ICMTS is designed to regulate the flow of transcritical gas or subcritical liquid from the gascooler in transcritical CO 2 File Size: 1MB.

Chapter 17 - Control Valve Troubleshooting The purpose of this chapter is to provide the plant engineer with a useful guide to troubleshooting control valve problems. The chapter looks at control valve problems from the standpoint of specification, installation, and commissioning.

motor operated valve - fire case zh (Petroleum) (OP) 3 Dec 08 Hello We have in the project motor operated valves which are interlocked with pumps, compressors. They have to be closed in case of fire. Fluid is flammable and toxic. We have 3 pushbuttons "Stop"- on the actuator, on the panel somewhere on the field, on the pump/compressor.

@article{osti_, title = {Motor-operated valve (MOV) actuator motor and gearbox testing}, author = {DeWall, K and Watkins, J C and Bramwell, D}, abstractNote = {Researchers at the Idaho National Engineering and Environmental Laboratory tested the performance of electric motors and actuator gearboxes typical of the equipment installed on motor-operated valves used in nuclear power plants.

Please note: If you want to save searches or use IEEE Xplore alerting services, you still need to register for an IEEE Account. Learn more about Athens and Shibboleth. IEEE Account.The Motor Operated Valve (MOV) Design Basis Course offers a combined classroom and laboratory educational experience dedicated to the functionality of Safety-Related Motor-Operated Valves under Design-Basis conditions.

SinceISU has been able to establish and maintain a highly respected technical training program, initially focused on training US Nuclear Regulatory Commission staff.Device numbers are specified in ANSI/IEEE Standard C and are used to identify the functions of a device shown on a schematic diagram.

Try our ANSI device number challenge. Initiating device, such as a control switch, that operates either directly or through other .